Need Help With Your Order?

Call our Team on 0115 6976 800

Novia  |  SKU: NV006

Novia VC2 Air Leakage & Vapour Check Laminate 1.5m x 50m 75m2

£95.83 Ex VAT
£115.00 Inc VAT
Shipping calculated at checkout.

Nationwide Delivery in 3-5 WORKING DAYS

  • £40 ex VAT Delivery

Need a next-day or named day delivery? Call Us.


Novia VC2 AVCL (air and vapour control layer) is a reinforced air-tight vapour check membrane specifically designed for use in timber-framed dwellings in insulated wall, roof and floor applications. 

Features flame-resistant additives that mean the membrane will not readily ignite, and a scrim-reinforced layer that makes it tear-resistant. Install on the “warm” (interior) side of your structure and pair with external breather membranes for the “cold” side. Secure with Novia tapes for a secure finish.

  • Supplied unfolded, in rolls
  • Designed to provide an Sd value of 2-6 metres
  • Translucent, reinforced and tear-resistant
  • 1.5m wide
  • CE Approved and CPR Compliant
  • Complies with BS EN 13984
  • Improves insulation performance
Length:  50m Roll
Width:  1.5m
Coverage: 75m2
Moisture Vapour Permeabilityin Sd: 2-6m
Moisture Vapour Resistance: 1-30 MNs/g
Reaction to Fire E Class

 

What is a VCL?

 Vapour Control Layers (VCLs) are designed to manage the passage of moisture through a building's exterior walls, foundations and rooves and limit condensation within the interstitial layer “between” rooves, walls and floors. Particularly in high-humidity areas like the UK, water-laden air can condense on these structures causing damage over the long term, and reducing the thermal performance of insulation. 

It is advised to seal your Vapour Control Layer with double-sided butyl tape, followed by a BOPP tape to improve airtightness and increase the efficacy of the Vapour Control Layer. 

How do I Apply a Vapour Control Layer?

A vapour control layer should be applied on the interior side of any wall, roof or flooring, over timber studs before the internal lining. It should be 100% sealed to the structure with double-sided butyl tapes, pre-applied to all areas where a fixing is to be made, and finished with metallised BOPP tapes to ensure a complete vapour seal.

It is best used in conjunction with a Breather Membrane applied to the exterior side of the structure.

For more information on use and specification, please download the data sheet for this product below. 

Data Sheets & Information

Need Help? Call our Team on 0115 6976 800
  • Size
    1.5m x 50m
  • Coverage (m²)
    75
  • Length
    50m
  • Width
    1.5m
  • Material
    Non-Woven Polypropylene

Do You Ship to My Address?

We deliver to most mainland UK addresses. If you are in one of the areas listed below and are unable to checkout, please give us a call to put together a custom quote.

Northern Ireland (BT), Isle of Wight (PO30-37), Isle of Man (IM), Scottish Highlands and Orkney Isles (PA, ML, EH, KA, G, KY, PH, DD, AB, IV, KW), Outer Hebrides and the Shetland Isles (HS, ZE) will incur additional charges and may also experience delivery delays.

How Much Will My Delivery Cost?

You can work out the cost of delivery on your order before checkout by heading to our Delivery Info page.

How Long Will Delivery Take?

We aim to deliver your items in 3 - 5 Working Days unless otherwise specified (eg - Sheds and Paving Kits). After you have placed your order, we will process your order and book a delivery day - which will then be sent to you via Email.

If have a specific request, please do give our team a call on 01156976800 and we will do our best to help.

What If I Need to Return Something?

If for any reason you wish to return your purchase, we will offer a refund or an exchange as long as this is requested within 14 days of receiving your order.

A manufacturer’s restocking charge may also apply on certain products such as non-stock items, which may be up to 30% of the purchase price, and you will be notified of this amount when you request a refund or exchange.

For full information visit our Returns Policy.

Novia VC2 Air and Vapour Check Roll
Novia

Novia VC2 Air Leakage & Vapour Check Laminate 1.5m x 50m 75m2

£95.83 Ex VAT
£115.00 Inc VAT

Novia VC2 AVCL (air and vapour control layer) is a reinforced air-tight vapour check membrane specifically designed for use in timber-framed dwellings in insulated wall, roof and floor applications. 

Features flame-resistant additives that mean the membrane will not readily ignite, and a scrim-reinforced layer that makes it tear-resistant. Install on the “warm” (interior) side of your structure and pair with external breather membranes for the “cold” side. Secure with Novia tapes for a secure finish.

Length:  50m Roll
Width:  1.5m
Coverage: 75m2
Moisture Vapour Permeabilityin Sd: 2-6m
Moisture Vapour Resistance: 1-30 MNs/g
Reaction to Fire E Class

 

What is a VCL?

 Vapour Control Layers (VCLs) are designed to manage the passage of moisture through a building's exterior walls, foundations and rooves and limit condensation within the interstitial layer “between” rooves, walls and floors. Particularly in high-humidity areas like the UK, water-laden air can condense on these structures causing damage over the long term, and reducing the thermal performance of insulation. 

It is advised to seal your Vapour Control Layer with double-sided butyl tape, followed by a BOPP tape to improve airtightness and increase the efficacy of the Vapour Control Layer. 

How do I Apply a Vapour Control Layer?

A vapour control layer should be applied on the interior side of any wall, roof or flooring, over timber studs before the internal lining. It should be 100% sealed to the structure with double-sided butyl tapes, pre-applied to all areas where a fixing is to be made, and finished with metallised BOPP tapes to ensure a complete vapour seal.

It is best used in conjunction with a Breather Membrane applied to the exterior side of the structure.

For more information on use and specification, please download the data sheet for this product below. 

Data Sheets & Information

View product