  • £40 ex VAT Delivery

Need a next-day or named day delivery? Call Us.


A premium spec reinforced and foil-laminated polythene Vapour Control Layer (VCL), The Novia STRP Pro is a high-performance membrane designed for use in insulated walls, floors and roofing, particularly where high concentrations of moisture vapour (such as warm flat rooves) require control.


Ideal for metal profile-clad industrial buildings, education sector and commercial properties, it is extra-tough, tear-resistant and reinforced with an aluminium foil core. Install on the “warm” (interior) side of your structure and pair with external breather membranes for the “cold” side. Secure with Novia tapes for a secure finish.

  • Supplied unfolded, in rolls
  • Offers improved r-value when installed facing a minimum 25mm air gap
  • Reinforced and tear-resistant
  • 1.6m wide
  • CE Approved and CPR Compliant
  • Complies with BS EN 13984
  • Improves insulation performance
Length:  50m Roll
Width:  1.6m
Coverage: 80m2
Moisture Vapour Permeabilityin Sd: 4000m
Moisture Vapour Resistance: 4000 MNs/g
Reaction to Fire NPD Class
Reflectivity  57% 

 

What is a VCL?

 Vapour Control Layers (VCLs) are designed to manage the passage of moisture through a building's exterior walls, foundations and rooves and limit condensation within the interstitial layer “between” rooves, walls and floors. Particularly in high-humidity areas like the UK, water-laden air can condense on these structures causing damage over the long term, and reducing the thermal performance of insulation. 

It is advised to seal your Vapour Control Layer with double-sided butyl tape, followed by a BOPP tape to improve airtightness and increase the efficacy of the Vapour Control Layer. 

How do I Apply a Vapour Control Layer?

A vapour control layer should be applied on the interior side of any wall, roof or flooring, over timber studs before the internal lining. It should be 100% sealed to the structure with double-sided butyl tapes, pre-applied to all areas where a fixing is to be made, and finished with metallised BOPP tapes to ensure a complete vapour seal.

It is best used in conjunction with a Breather Membrane applied to the exterior side of the structure.

For more information on use and specification, please download the data sheet for this product below. 

Data Sheets & Information

Need Help? Call our Team on 0115 6976 800
  • Size
    1.6m x 50m
  • Coverage (m²)
    80
  • Length
    50m
  • Width
    1.6m
  • Material
    Reinforced Polythene

Do You Ship to My Address?

We deliver to most mainland UK addresses. If you are in one of the areas listed below and are unable to checkout, please give us a call to put together a custom quote.

Northern Ireland (BT), Isle of Wight (PO30-37), Isle of Man (IM), Scottish Highlands and Orkney Isles (PA, ML, EH, KA, G, KY, PH, DD, AB, IV, KW), Outer Hebrides and the Shetland Isles (HS, ZE) will incur additional charges and may also experience delivery delays.

How Much Will My Delivery Cost?

You can work out the cost of delivery on your order before checkout by heading to our Delivery Info page.

How Long Will Delivery Take?

We aim to deliver your items in 3 - 5 Working Days unless otherwise specified (eg - Sheds and Paving Kits). After you have placed your order, we will process your order and book a delivery day - which will then be sent to you via Email.

If have a specific request, please do give our team a call on 01156976800 and we will do our best to help.

What If I Need to Return Something?

If for any reason you wish to return your purchase, we will offer a refund or an exchange as long as this is requested within 14 days of receiving your order.

A manufacturer’s restocking charge may also apply on certain products such as non-stock items, which may be up to 30% of the purchase price, and you will be notified of this amount when you request a refund or exchange.

For full information visit our Returns Policy.

Novia STRP Pro - Foil Reflective VCL Vapour Control Layer
Novia

Novia STRP Pro High Performance Reinforced Foil VCL 1.6m x 50m 80m2

£183.33 Ex VAT
£220.00 Inc VAT

A premium spec reinforced and foil-laminated polythene Vapour Control Layer (VCL), The Novia STRP Pro is a high-performance membrane designed for use in insulated walls, floors and roofing, particularly where high concentrations of moisture vapour (such as warm flat rooves) require control.


Ideal for metal profile-clad industrial buildings, education sector and commercial properties, it is extra-tough, tear-resistant and reinforced with an aluminium foil core. Install on the “warm” (interior) side of your structure and pair with external breather membranes for the “cold” side. Secure with Novia tapes for a secure finish.

Length:  50m Roll
Width:  1.6m
Coverage: 80m2
Moisture Vapour Permeabilityin Sd: 4000m
Moisture Vapour Resistance: 4000 MNs/g
Reaction to Fire NPD Class
Reflectivity  57% 

 

What is a VCL?

 Vapour Control Layers (VCLs) are designed to manage the passage of moisture through a building's exterior walls, foundations and rooves and limit condensation within the interstitial layer “between” rooves, walls and floors. Particularly in high-humidity areas like the UK, water-laden air can condense on these structures causing damage over the long term, and reducing the thermal performance of insulation. 

It is advised to seal your Vapour Control Layer with double-sided butyl tape, followed by a BOPP tape to improve airtightness and increase the efficacy of the Vapour Control Layer. 

How do I Apply a Vapour Control Layer?

A vapour control layer should be applied on the interior side of any wall, roof or flooring, over timber studs before the internal lining. It should be 100% sealed to the structure with double-sided butyl tapes, pre-applied to all areas where a fixing is to be made, and finished with metallised BOPP tapes to ensure a complete vapour seal.

It is best used in conjunction with a Breather Membrane applied to the exterior side of the structure.

For more information on use and specification, please download the data sheet for this product below. 

Data Sheets & Information

View product